Qualify the fluorescence performance of the SpectraMax . The chamber contains springs that position the cuvette in the proper alignment for a read. Description: The SpectraMax® iD5 Multi-Mode Microplate Reader is the complete laboratory solution to help you increase your research. A two-fold dilution series of JQ1 (in DMSO) starting from 1 μM was prepared. 5. SpectraMax® M3, M4, M5, and M5e Multi-Mode Microplate Readers User Guide 0112-0115 F July 2010 M3-M5e_manual. The SpectraMax M5, M5e, and. 筛选时,SpectraMax M5多功能微孔板读板 机可作为其非常理想的、可靠的检测平台。 SpectraMax M5是一种基于光栅型单色器 的多功能微孔板读板机,允许使用者针对不 同的荧光染料分子随意选择不同的检测波 长,而无需额外再选购滤光片配件。这篇应 FlexStation® 3 Multi-Mode Microplate Reader. 4, Z’ = 0. 0 nm increments Bandwidth (EX, EM) 9 nm, 15 nm Optimized Precision ≤ 3. The SpectraMax M5, M5e, and FlexStation 3 Multi-Mode Microplate Readers have been validated for use with the ValitaTiter and ValitaTiter Plus assays. FP assay do not perform well with protein:protein interactions. The Analyst®, FlexStation® and SpectraMax® M5/M5e from Molecular Devices have received the LanthaScreen® Certified designation from Invitrogen™ which ensures that these readers are validated to strict standards in instrument seFigure 2: Expression of mCherry with (improved BBa_K1141000) and without (BBa_K1141000) the translation enhancing 5’ untranslated region was measured (Ex: 587 nm, Em: 610 nm) over a period of 6 hours after induction with 0. The SpectraMax M5e Multi. e. 1. SpectraMax M5eは、宇宙に打ち上げられた世界初のマイクロプレートリーダーです! NanoRacksとモレキュラーデバイスとのパートナーシップ、そしてSpaceX Commercial Resupply Services MissonでSpectraMax M5eを打ち上げた取り組みの詳細については、こちらをクリックしてください。SpectraMax ® ® M5e readers must be appropriately configured for HTRF ® readout by setting up the measurement conditions in the SoftMax Pro software. The SpectraMax® Plus 384 Microplate Reader from Molecular Devices can run both standard spectrophotometer and microplate reader applications on the same instrument. ® reader to the computer. SpectraMax Plus, Plus384, M2, M2e, M5e or M5 readers). For a complete list of the instruments supported by this release of the SoftMax Pro Software, see Supported Instruments on page 111. com 10. Note: for the THUNDER assay, performance of a SpectraMax M5e reader will be equivalent to that of a SpectraMax M5 reader. 1. 5 mP standard deviation at 1 nMOEM: Molecular DevicesMaterial: SpectraMax M5e Common Name: Microplate Spectrophotometer Item Weight: 36 Serial Number: MVE06577 SKU#: Inv-00352193. This document is provided to customers who have purchased Molecular Devices, Inc. SpectraMax M5e Multi-Mode Microplate Reader. Each tube of fluorophore also contained ROX. The SpectraMax ® M3, M4, M5, and M5 e Microplate Readers are a series of dual-monochromator, multidetection, multi-mode instruments with a triple-mode cuvette port and 6-well to 384-well microplate reading SpectraMax i3 Install Guide; SpectraMax i3; SpectraMax i3x; SpectraMax iD3; SpectraMax iD5; SpectraMax Mini; SpectraMax Mini Install Guide; SpectraMax Mini Reader Plug-In Download Page (required for SoftMax Pro 7. 72 MB. 1. The Analyst®, FlexStation® and SpectraMax® M5/M5 e from Molecular Devices have received the LanthaScreen® Certified designation from Life Technologies which ensures that these readers are validated to strict standards in instrument setup and assay performance. Optimal instrument settings are the same for all three readers. Fluorescent Polarization: Solid black plates, as above. Multimode Readers Comparison Chart. Listing SKU: DIS-58825-molecular-devices-spectramax-m5e-microplate-readerIn May 2011, Molecular Devices SpectraMax M5e reader, chosen for its durability, became the first microplate reader in space. M5e: W = 15. 00 - Original price $5,513. The Molecular Devices SpectraMax M5E is a multi-mode plate reader that delivers single mode reader performance with five preferred detection modes for a wide range of applications. The SpectraMax® M2 and M2e readers provide two detection modes in one platform, and offer the the added functionality of bottom-read fluorescence for cell-based assays (M2e). These were dispensed directly into a microplate and did not require any thermal cycling. book Page 1 Wednesday, July 7, 2010 2:09 PM. 5 Z’ factor 0. #6016736) ATP standards ranging from 1 µM to 1 pM were prepared as. 1)M5e = 174nM SpectraMax M5e delta F % Paradigm = 18nM M5e = 19nM Figure 1. After excluding the background values, the cross‐reactivity of the. The Analyst®, FlexStation® and SpectraMax® M5/M5e from Molecular Devices have received the LanthaScreen® Certified designation from Invitrogen™ which ensures that these readers are validated to strict standards in instrument seSpectramax i3x multi-mode detection platformMolecular devices spectramax m5e manual I3x spectramax microplate reader multi mode molecular devices minimax cytometer imaging selectscienceSpectramax i3 injury biomechanics medicine materials center. 315 can't find zero order. E3300S/L) can be found on the New. $. 2 x 10-14. Simultaneous dual emission detection enables read times of only 2:17 for an entire 384-well plate. With optimized reagents, option to operate the. IMAP assays are based on binding of. SpectraMax Injector Cartridge with SmartInject™ Technology. Description 1. 8 x 10-15. SpectraMax M Series Multi-Mode Microplate Readers | MolecularSpectraMax L: 36. Products : SpectraMax M2/M2e reader, SpectraMax M5/M5e reader, Gemini XPS reader, FlexStation II (Obsolete), Gemini EM reader, FlexStation 3 reader Fluorescence Microplate Reader Comparison Chart Features We would like to show you a description here but the site won’t allow us. The SpectraMax M2 and M2e systems provide the multi detection microplate readers with dualmonochromators, dual-mode cuvette ports, with top & bottom reading. The Analyst®, FlexStation® and SpectraMax® M5/M5e from Molecular Devices have received the LanthaScreen® Certified designation from Invitrogen™ which ensures that these readers are validated to strict standards in instrument seFor calcium content quantification, separate plates were used. 3. The optical systems use two scanning monochromators soThe SpectraMax® Mini Multi-Mode Microplate Reader offers a budget friendly solution that gives you exactly what you need when you need it. The guide also covers the software features, the specifications, and the accessories of the systems. 1(a). 3. The Molecular Devices Gemini XS Fluorescent Microplate Reader lets you experiment with a variety of fluorophores and can even find the best excitation and emission wavelengths for new assays. SpectraMax M3, M4, M5, and M5e Microplate Reader User Guide Cuvette Chamber The cuvette chamber is located to the right of the control panel. SpectraMax M5. Once the M5e Reader is operational, space-based researchers will be able to conduct analysis on-orbit. 00. About Conquer. Microplate Readers include the M3, M4,. It offers the additional advantage of HTRF ® (homogeneous time-resolved fluorescence) certification, allowing. Pick the best speed, sensitivity, and price for your needs. Assay used: ATPlite 1step Luminescence Assay System (PerkinElmer cat. The following document is intended to demonstrate setup of this instrument and provide representativeThe SpectraMax® M3, M4, M5 and M5e Multi-Mode Microplate Readers are a modular, upgradeable dual-monochromator microplate reader platform offering a wide range of high performance multi-mode capabilities ideal for life science research and drug discovery screening. AVALANCHE. SpectraMax M5e Reader only Certified to Cisbio Bioassays’ HTRF technology performance specifications Fluorescence Polarization Performance (M5/M5e only) Wavelength range 300–750 nm Wavelength selection Monochromators, tunable in 1. edu) to be added as a trained user in iLab. the SpectraMax M5e, one of Molecular Devices most reliable and feature-rich microplate readers, to operate comfortably in the zero-gravity environment of the space station. Ex wavelength (nm/bandwidth) 485/20. Spectranet customer portalBioTek Cytation™ 5 Cell Imaging Multi-Mode Reader. The optical systemsThe SpectraMax® M2 and M2e readers provide two detection modes in one platform, and offer the the added functionality of bottom-read fluorescence for cell-based assays (M2e). Twelve different automated tests are provided: • Fluorescence lower limit of detection (LLD) • Excitation wavelength accuracy • Emission wavelength accuracy • Excitation wavelength precision SpectraMax® M5e Multi-Mode Microplate Reader performance with an integrated 8- or 16-channel pipettor into one compact benchtop reader. 7°C (gradient heating design). Cyclic AMP titration curves were evaluated using SpectraMax Paradigm and SpectraMax M5e instruments. The SpectraMax® M2 and M2e readers provide two detection modes in one platform, and offer the the added functionality of bottom-read fluorescence for cell-based assays (M2e). KeySpan adapter for SoftMax Pro and SpectraMax readers. UV/Visible multi-mode reader absorbance, providing ultrafast, full spectral range. SPECTRAMAX XS XENON REPLACEMENT BULB FOR MOLECULAR DEVICES SPECTRAMAX XPS XENON, SPECTRAMAX XS. Description 1. 0112-0115G October2018 SpectraMax®M3 SpectraMax®M4 SpectraMax®M5 SpectraMax®M5e Multi-ModeMicroplateReaders UserGuidethe SpectraMax M5e, one of Molecular Devices most reliable and feature-rich microplate readers, to operate comfortably in the zero-gravity environment of the space station. 01 1 100 10000 1000 2000 3000 SpectraMax Paradigm SpectraMax M5e [cAMP] nM delta F % EC 50 Values Paradigm = 18nM M5e = 19nM Variation of Integration Time-12 -10 -8 -6 -4 5000 10000 15000 20000 25000 50 s. 3. INTRODUCTION The SpectraMax M2 and SpectraMax M2 e Multidetection Readers are monochromator based microplate readers that have 6well to 38 4well microplate reading capability as well NanoRacks, LLC is installing a new, reconfigured Molecular Devices’ SpectraMax M5e multi-mode microplate reader on the International Space Station to perform experiments in microgravity. The following document is intended to demonstrate setup of this instrument. book Page 1 Wednesday, July 7, 2010 2:09 PM The Molecular Devices SpectraMax M5e Microplate Reader enables five modes of detection. Molecular Devices Corporation. SpectraMax M5e: 118. Molecular Devices SpectraMax M5e User Manual (20 pages) Multi-Mode Microplate Readers. The SpectraMax® M3, M4, M5 and M5e Multi-Mode Microplate Readers are a modular, upgradeable dual-monochromator microplate reader platform offering a wide range of high performance multi-mode capabilities ideal for life science research and drug discovery screening. SpectraMax M3, M4, M5, and M5 e. Multi-Mode Microplate Readers including the M3, M4, M5, and M5. G-protein coupled receptors signal through two major pathways, regulation of cAMP and increase in intracellular calcium levels mediated by IP3. 2 only) SpectraMax M-series Microplate readers. elegans, and Alcanivorax borkumensis. Molecular Devices FlexStation™ 3 Multi-Mode Microplate Reader w/ One Year Warranty (Svc Contract Available) ATG for AKTA Explorer, Purifier and FPLC PMs, Repairs and Service Contracts. Following the user manual for installation, maintenance, assembly or troubleshoot is an crucial prerequisite for safety in addition to protect consumers from any liability from the manufacturer of the product for viable defects in case of an insurance claim. Bioz Stars score: 86/100, based on 1 PubMed citations. Also refer to this Multimode Reader Comparison Chart. 92 0. SpectraMax Mini: 17. In particular, these parameters should be entered as defined in the table below. • SpectraMax® M3/M4/M5/M5e Multi-Mode Microplate Readers • SpectraMax® Paradigm® Multi-Mode Microplate ReaderThe SpectraMax M5e Microplate Reader enables five modes of detection with the additional benefit of being certified for Cisbio Bioassays’ HTRF Assays. SpectraMax M5eは、2011年に国際ステーションで使用されるプレートリーダーとして初めて採用されました。 SpectraMAx Mシリーズプレートリーダーは発売以来、「壊れにくい装置」として認知されており、今なお採用され続けている実績のある装置です。Products : SpectraMax M2/M2e reader, SpectraMax M3 reader, SpectraMax M4 reader, SoftMax Pro Software, SpectraMax Plus 384 reader, SpectraMax 190 reader, SpectraMax 340PC 384 (Obsolete), SpectraMax M5/M5e reader Why does "Path?" appears in all wells when PathCheck is selected? Cause: Water Constants. (“Molecular Devices”) equipment, software, reagents, and consumables to use in the. This Molecular Devices SpectraMax M5e Multi-Mode Microplate Reader is in good working order. SpectraMax® iD5. Jeffrey Manber, Managing Director of NanoRacks said, "Having the SpectraMax M5e Reader on-orbit will allow researchers to undertake research with real-time results. Delivers single mode reader performance in one multimode reader package. Add to cart. FlexStation™ II. On SpectraMax L, 1 RLU = 1 count per second for photon counting mode only. Five preferred detection modes. SpectraMax Mini: 17. Brand: Molecular Devices | Category: Laboratory Equipment | Size: 0. IMAP phosphodiesterase assays on SpectraMax Multi-Mode Microplate Readers. The SpectraMax® M3, M4, M5 and M5e readers offer a modular, upgradeable dual monochromator microplate reader platform with a wide range of high performance multi. Choose from a three- (M3), four- (M4), orHome; Lighting; Work lights; User manual. book Page 1 Wednesday, July 7, 2010 2:09 PM SpectraMax M3, M4, M5, and M5 e Multi-Mode Microplate Readers 0112-0115 F 9 PathCheck ® Pathlength Meas urement Technology A SpectraMax Multi-Mode Microplate Reader with PathCheck Pathlength Measurement Technology allows normalization of variable well volumes to 1-cm cuvette readings. com A. We would like to show you a description here but the site won’t allow us. 2 x 10-14. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a. At the low light level (approaching the Lower. the SpectraMax M5e, one of Molecular Devices most reliable and feature-rich microplate readers, to operate comfortably in the zero-gravity environment of the space station. Products : SpectraMax M2/M2e reader, SpectraMax M5/M5e reader, Gemini XPS reader, SpectraMax Plus 384 reader, SpectraMax 190 reader, VersaMax reader, FlexStation 3 reader I need to reinstall the USB driver for my plate reader. Introduction. OD 450 nm was measured by SpectraMax M5e. With SpectraMax M Series readers, there is no need to utilize expensive filters to optimize detection levels and background. Keywords: spectramax m2 systems, spectramax m2e systems, spectramax m2/m2e readers, pathcheck sensor, spectratest abs1 absorbance, stakmax stacker Created Date: 5/20/2019 9:24:38 AM The SpectraMax® iD3 and iD5 Multi-Mode Microplate Readers measure absorbance, fluorescence, and luminescence. 1) SpectraMax Glo Steady Luc Reporter Assay (6. 9000-0756. 90 Read time (384 wells) 5:03 2:17 14:00 Table 3. Introduction Inflammation, the body’s reaction to infection, irritation, or other injury, is accompanied by increased endothelial chemokine. SpectraMax Absorbance, Fluorescence, Luminescence, and Multi-Mode Readers. Note: In this user guide, SpectraMax ® refers to several SpectraMax . com. Luciferase reporter assays are widely used because of their sensitive detection capacity and broad dynamic range. 00 USD. The detector is a CCD array with 512 pixels in x and 512 pixels in y. Thermo Lab Systems Multiskan Ascent 354 $1,400. SpectraMax® M5. ₹ 1,80,000 Get Latest Price. book Page 1 Wednesday, July 7, 2010 2:09 PM. The optical systemsSUNNYVALE, Calif. These settings are also valid for the SpectraMax M3/M4 and FlexStation® 3 Multi-Mode Microplate Readers. GE AKTA™ Crossflow. Explore PDF for more details. (“Molecular Devices”) equipment, software, reagents, and consumables to use in the. For wavelengths in the UV range above 220 nm,. -- JULY 19, 2016Cables. Using the patented PathCheck® Pathlength Measurement Technology, the SpectraMax M5e Microplate Reader transforms each well in a microplate to a fixed. Real-time fluorescence signals were recorded using CFX96 thermocycler (Bio-Rad). Molecular Devices recommends that you use high-quality, doubleshielded cables to connect your SpectraMax. S. Fig 1. Located at the right front of the SpectraMax Plus 384, the cuvette chamber has a lid that lifts up, allowing you to insert or remove a cuvette. This document is provided to customers who have purchased Molecular Devices, Inc. The SpectraMax iD5 and SpectraMax i3x readers use SoftMax® Pro Data Acquisition and Analysis Software. Upgrades to the original platform include temperature control and the ability to configure every aspect of the researcher’s experiment fromMolecular Devices SpectraMax™ M5e Microplate Reader w/ Warranty (Svc Contract Available) $34,000. The mirror set. 1. HTRF is compatible with a large range of available microplate readers. After the firefly luciferase was measured, Dual-Glo Stop & Glo substrate solution (25 µL/well) was added offline to each well to quench the firefly luciferase reaction and provide substrate for the Renilla luciferase reaction. Jul 13, 2023 10am PT Date Format. #6016736) ATP standards ranging from 1 µM to 1 pM were prepared as. 0 nm increments Bandwidth (EX, EM) 9 nm, 15 nm Optimized Precision ≤ 3. 312 gain calibration failed. GFP fluorescence was read on days 1, 4 and 7, using a SpectraMax M5e Microplate Reader (Molecular Devices). 0 nm increments Bandwidth (EX, EM) 9 nm, 15 nm Optimized Precision ≤ 3. 8 x 10-15. FlexStation II. SUNNYVALE, Calif. FlexStation II 384. After The Plate Is Read, Data Will Appear In The Plate Section: 11. The SpectraMax M5/M5e & FlexStation 3 instruments use SoftMaxPro® Data Acquisition & Analysis Software. SpectraMax® M3, M4, M5, and M5e Multi-Mode Microplate Readers User Guide 0112-0115 F July 2010 M3-M5e_manual. Luciferase Detection Instrumentation Guide. This integrated system provides users with a multi-detection platform capable of increasing the liquid handling throughput and flexibility for biochemical- and cell-based kinetic assays. HTRF is a versatile TR-FRET technology developed by Cisbio for detecting biomolecular interactions. Accurate quantitation The optical design of the SpectraMax 340PC384 reader truly mimics a dual. With only a few product lines that we provide service for, our engineers have unrivaled expertise in the SpectraMax® microplate readers. 3. 3. SoftMax Pro 软件模板设置之一标准曲线的绘制以及样品浓度的自动计算. book Page 1 Wednesday, July 7, 2010 2:09 PM. 005) Photometric Precision多功能酶标仪SpectraMax M5e. The Spectr. Molecular Devices SpectraDrop ™ Micro-Volume Microplate allows users to read up to 64 samples per plate on SpectraMax ® Microplate Readers, with sample volumes as low as 2 µL. 01 1 100 10000 1000 2000 3000 SpectraMax Paradigm SpectraMax M5e [cAMP] nM delta F % EC 50 Values Paradigm = 18nM M5e = 19nM Variation of Integration Time-12 -10 -8 -6 -4 5000 10000 15000 20000 25000 50 s delay 400 50 s. e. The SpectraMax® M3, M4, M5 and M5e readers offer a modular, upgradeable dual monochromator microplate reader platform with a wide range of high performance multi. UT-6550 Microplate Reader is a reliable and robust instrument for a wide. These robust readers have been placed in labs from Antarctica to the. For more information please visit us at: SpectraMax®i3Multi-ModeMicroplateReader* SpectraMax®i3xMulti-ModeMicroplateReader*. Twelve different automated tests are provided: • Fluorescence lower limit of detection (LLD) • Excitation wavelength accuracy • Emission wavelength accuracy • Excitation wavelength precisionSpectraMax® M5e Multi-Mode Microplate Reader performance with an integrated 8- or 16-channel pipettor into one compact benchtop reader. Recertification is recommended every two years. Cell monolayers were decalcified with 0. Dual monochromators for assay flexibility With SpectraMax M Series readers, there is no need to utilize expensive filters to optimize detection levels and background. The schematic of the UED setup is shown as Fig. For fluorescence intensity assays, users can select from top- or bottom-read modes for improved sensitivity in solution and cell-based assays. Skatron Skanwasher 300 Washer. 28 nM to 0. 97 cAMP Detection AssayThe SpectraMax M5e reader offers the additional benefit of being certified . We would like to show you a description here but the site won’t allow us. SpectraMax ABS Plus SpectraTest ABS2 v1. 90 0. Recommended Optics Wavelength (nm) Wavelength selection Excitation 405/9 Monochromator Emission 1 450/15 Monochromator SpectraMax M5e Reader only Certified to Cisbio Bioassays’ HTRF technology performance specifications Fluorescence Polarization Performance (M5/M5e only) Wavelength range 300–750 nm Wavelength selection Monochromators, tunable in 1. SpectraMax M2. 5. assays on the SpectraMax® Paradigm® microplate detection platform. Cells were allowed to attach and grow overnight at. The donor and acceptor can be used to label a variety of biomolecules, for. Molecular Devices FilterMax F5 Multi-Mode Microplate Reader $7,900. The Analyst®, FlexStation® and SpectraMax® M5/M5 e from Molecular Devices have received the LanthaScreen® Certified designation from Life Technologies which ensures that these readers are validated to strict standards in instrument setup and assay performance. 1. 1. 00 USD. The SpectraMax® M5e includes htrf certification, and both the M5 and M5e are lanthascreen certified. Oxygen consumption is one of the most informative and direct measures of mitochondrial function. Testing we performed: The Molecular Devices SpectraMax M5e Multi-Mode Microplate Reader passed all tests and was found to be fully functional: Power: PASSED Initialization: PASSED Display/Buttons: PASSEDThe Challenge. The plate was agitated briefly, incubated 15 minutes at room temperature in the dark and read on M5e. 306 plate air cal fail,low light. The SpectraMax® M5e includes htrf certification, and both the M5 and M5e are lanthascreen certified. HTRF cAMP calibration curve HTRF cAMP calibration curve measured on the SpectraMax i3 (red circles), SpectraMax. FlexStation. Description 1. cAMP HiRange 0. LMax and LMax II RLUs are proportional to (counts/sec) x (integration time), so for these readers if the signal is constant, doubling the integration time doubles the RLU. Detection cartridge modularity allows for easy addition of new read modes within minutes without. 1. The SpectraMax® M5e Multi-Mode Microplate Reader from Molecular Devices delivers single-mode reader performance in one multi-mode reader package. D 1 1. #M5e) Methods Cell preparation. The optical systemsThe BioTek Synergy H1 multimode microplate reader is modular and upgradable to include variable-bandwidth monochromator optics for fluorescence excitation and emission wavelength selection, plus luminescence and UV-Vis absorbance. This integrated system provides users with a multi-detection platform capable of increasing the liquid handling throughput and flexibility for biochemical-based and cell-Molecular Devices’ SpectraMax® M5e Multi-Mode Microplate Reader Chosen to be the First Microplate Reader in Space by NanoRacks, LLC for NASA’s International Space Station Sunnyvale, CA – May 17th, 2011 – Today, Molecular Devices, a leading provider of instruments, software, and consumables for drug discovery and life sciences research,Configure your microplate reader. #6016736) ATP standards ranging from 1 µM to 1 pM were prepared as. (“Molecular Devices”) equipment, software, reagents, and consumables to use in the. You must scan the fluorochrome of interest in the SpectraMax M5 or M5e reader to determine the optimal excitation and emission wavelengths for your application. Molecular Devices SpectraMax M5e Microplate Reader. Jun 9th, 2023. #6016736) ATP standards ranging from 1 µM to 1 pM were prepared as. 5 mP standard deviation at 1 nMF1 SpectraMax Plus384andABSPlus: Certificate Value – 2≤ Average Peak Value≤ Certificate Value + 2 SpectraMax M2,M2e,M3,M4,M5,andM5e: Certificate Value – 3≤ Average Peak Value≤ Certificate Value + 3 Photometric Accuracy F2, F3, F4 AverageOD=Certificate Value± (Certificate Value(0. 5. book Page 1 Tuesday,. 8 x 10-15. Setup Guide. SpectraMax Paradigm Platform in conjunction with AlphaLISA provides a powerful tool to screen novel therapeutics in a pathologically relevant, endothelial cell-based model. 8. reader (TUNE) SpectraMax M5e. EUROPE +44-118-944-8000 Mon to Fri 8am - 5pm GMT. The dual monochromator optics allow the widest range of applications to be utilized for bioresearch and drug discovery applications, all without the need to change. In the M2, M5 and Plus. The SpectraMax® Plus 384 Microplate Reader from Molecular Devices can run both standard spectrophotometer and microplate reader applications on the same instrument. The new Molecular Devices instrument comes with a standard 1-year depot warranty service. spr SpectraMax iD3 SpectraTest ABS2 v1. 8. the performance of the Molecular Devices SpectraMax® M5e Multi-Mode Microplate Reader with an integrated 8-channel or 16-channel pipettor into one compact benchtop reader. The SpectraMax® M3, M4, M5 and M5e Multi-Mode Microplate Readers are a modular, upgradeable dual-monochromator microplate reader platform offering a wide range of high performance multi-mode capabilities ideal for life science research and drug discovery screening. The dual monochromator optics allow the widest range of applications to be utilized for bioresearch and drug. M3-M5e_manual. reader (FI-FLRH) SpectraMax Paradigm. 00 USD. Proceed with the following steps using optimized settings. Paradigm: W = 21. 1. Introduction. 6 x 10-15. Fluorescence polarization was measured using SpectraMax M5e plate reader (Molecular Devices): 485 nm excitation (9 nm bandwidth), 525 nm emission (15 nm bandwidth). 2 x 10-14. Join. 1. 1. Lector de microplacas M5E-SC SpectraMax M5e con contrato de servicio de 1 año - Lector de placas multimodo SpectraMax M5/M5e, dispositivos moleculares - cada uno . SpectraMax® iD5 Multi-Mode Microplate Reader - Five-Mode Hybrid Microplate Reader with Automatic NFC Filter Identification and Western Blot Capability, Molecular Devices. 1. 0 nm increments Bandwidth (EX, EM) 9 nm, 15 nm Optimized Precision ≤ 3. STAKMAX. SoftMax Pro Software is an industry-leading acquisition and analysis software with over 160 ready-to-run protocols, powerful data analysis, and a range of data output options. The dual monochromator optics allow. 00 $ 2,999. M3-M5e_manual. 1. Choose cables that meet the requirement described in this appendix. The SpectraMax ® M3, M4, M5, and M5 e Microplate Readers are a series of dual-monochromator, multidetection, multi-mode instruments with a triple-mode cuvette port. British Columbia, Selkirk Mountains. Molecular. 5 mP standard deviation at 1 nMMolecular Devices SpectraMax M5e Microplate Reader $26,500. This document is provided to customers who have purchased Molecular Devices, Inc. For example, microplates containing different samp les can be read using the same orSpectraMax M5e Reader only Certified to Cisbio Bioassays’ HTRF technology performance specifications Fluorescence Polarization Performance (M5/M5e only) Wavelength range 300–750 nm Wavelength selection Monochromators, tunable in 1. SpectraMax L Microplate Reader is a sensitive luminometer with programmable injector options that measures flash and glow luminescence assays, including dual luciferase reporter gene, G protein-coupled receptor (GPCR) in 96- and 384-well plates. Share Tweet Share Pin. . The measurements were performed in triplicate. Table of Contents. ZERO BIAS - scores, article reviews, protocol conditions and more-Dual monochromatic optics -Wide range of applications -Top or bottom read modes The SpectraMax M3 Multi-Mode Microplate Reader provides three modes of detection in one platform The SpectraMax M3 Microplate Reader is the standard for UV/visible multi-mode reader absorbance, providing ultrafast, full spectral range. The Analyst®, FlexStation® and SpectraMax® M5/M5 e from Molecular Devices have received the LanthaScreen® Certified designation from Life Technologies which ensures that these readers are validated to strict standards in instrument setup and assay performance. SpectraMax Quant dsDNA Assay Kits. Bookings are free, but you will need to use iLab to book. 508/20. Configure your microplate reader. Dual monochromators for assay flexibility With. Brand: Molecular Devices | Category: Laboratory Equipment | Size: 0. The Molecular Devices SpectraMax M5 is a multi-mode plate reader that delivers single mode reader performance with five preferred detection modes for a wide range of applications. 5. 1. Endpoint, kinetic, spectrum. The SpectraMax M5e reader offers the additional benefit of being certified for Cisbio Bioassays HTRF® technology. The user must ensure that the meniscus is comfortably above the light beam in standard cuvettes and that the sample chamber in a microcuvette is aligned properly with the beam. Two cynomolgus monkeys (1 male and 1 female) weighing 2–4 kg and 3–5 years old were purchased from Suzhou. For more information about the SpectraMax® M5e Multi-Mode Microplate Reader or other products from Molecular Devices, please visit our website (or send an email to. The SpectraMax® M2 and M2e Systems from Molecular Devices are multidetection microplate readers with dualmonochromators, dual-mode cuvette ports, and top- and bottom-reading capability (top-reading only on the M2). . 8 x 10-15. 4. 6 M HCl for 24 h. 40266 Email: drugdiscoverytech@lifetech. With SpectraMax M Series readers, there is no need to utilize expensive filters to optimize detection levels and background. SpectraMax M3, M4, M5, and M5e Microplate Reader User Guide Cuvette Chamber The cuvette chamber is located to the right of the control panel. The SpectraMax M5e Multi-Mode Microplate Reader features a triple-mode cuvette port, temperature control, microplate shaking, and the industry leading SoftMax Pro. SpectraMax® M3, M4, M5, and M5e Multi-Mode Microplate Readers User Guide 0112-0115 F July 2010 M3-M5e_manual. Cellular Imaging Systems: Molecular Devices offers various imaging solutions for your research needs. reader. SpectraMax® M5e. The SpectraMax M5e reader offers the additional benefit of being certified for Cisbio Bioassays HTRF® technology. The M5 has two PMTs. Instruments and Settings for Fluorescence Read-out (Other Fluorescent Assays) FLUOstar Omega, VANTAstar, CLARIOstar, PHERAstar, PolarStar Optima. 0 Cell Viability Assay exhibits the same high performance as the classic CellTiter-Glo® Assay, making it suitable for use from benchtop scale to high-throughput screening. The system had to pass vibration load, zero gravity, and temperature fluctuation testings. In this application note we show how the SpectraMax ® i3, SpectraMax ® Paradigm ®, and SpectraMax ® M5e Multi-Mode Microplate Readers are used to perform robust, high-throughput HTRF ® assays with excellent Z’ factors and highly reproducible EC 50 values. View the Molecular Devices website. book Page 55 Wednesday, July 7, 2010 2:09 PM. The Quant-iT RiboGreen RNA Assay Kit, when run on a SpectraMax microplate reader with fluorescence detection mode and SoftMax Pro Software, is a rapid, sensitive detection method for RNA. Introduction. AlphaScreen assays cannot be done on the SpectraMax M series, Gemini, and SpectraMax iDx (iD3/iD5) readers. book Page 1 Wednesday, July 7, 2010 2:09 PM. Purchase of Additional 1 Year Service Plan includes: MRC Essential Service Plan, including parts, labor, and shipping/handling costs for emergency repairs. Conquer Scientific provides laboratories around the world high quality, low-cost pre-owned laboratory instruments. spr SpectraMax iD5 SpectraTest ABS2 v1. 1 or greater versions. SpectraMax M5e: 118. Whether you are looking for an intuitive, easy-to-use reader for your busy, multi-user lab, or an upgradeable system that can adapt to support your lab’s new projects andThe SpectraMax® M2 and M2e Multimode Microplate Readers provide two detection modes in one platform and offer the added functionality of bottom-read fluorescence for cell-based assays. 1, right panel), for rapid, real-time high throughput screening of mitochondrial (dys) function. book Page 21 Wednesday, July 7, 2010 2:09 PM. . M3,M4,M5,M5e,FlexStation 3 0200-6186 SpectraTest LM1 Luminescence ValidationPlate SpectraMaxiD3,iD5,i3x,i3,M3,M4,M5,M5e,SpectraMaxL, FlexStation 3 0200-2420Products : SpectraMax M2/M2e reader, SpectraMax Plus 384 reader, SpectraMax M4 reader, SpectraMax M5/M5e reader, SpectraMax M3 reader. 7°C and the bottom to 36. Products : SpectraMax M3 reader, SoftMax Pro Software, SpectraMax M5/M5e reader, SpectraMax L reader, SpectraMax M4 reader Is the Gaussia Luciferase (GLuc) Assay from New England Biolabs compatible with my plate reader? The information for the GLuc Assay Kit (Cat no. Supplier: Molecular Devices. 00. Figure 2 shows an increased expression of the improved. Transcreener® HTS is a universal, high throughput biochemical assay platform based on the detection of nucleotides, which are formed by thousands of cellular enzymes—many of which catalyze the covalent regulatory. View full details Original price $5,513. 0200-0729. Anne T. The validation kit included individual tubes of diluted fluorophores: FAM, HEX, and FAM+HEX. The self-funded NanoRacks Plate Reader-2 features a wide range of high-performance multi. Using the patented PathCheck® Pathlength Measurement Technology, the SpectraMax M5e Microplate Reader transforms each well in a microplate to a fixed. Enzyme Activation Analysis; RIDASCREEN Gliadin competitive ELISA;. 1. • SpectraMax M5e Multi‐Mode Microplate Reader • FlexStation® 3 Multi‐Mode Microplate Reader Overview. SpectraMax M 系列多功能微孔板读板机(酶标仪)可测定紫外光 (UV) 和可见光 光吸收、荧光、发光、荧光偏振、时间分辨荧光 (TRF) 和均相时间分辨荧光 (HTRF) 。. The SpectraMax M5e reader offers the additional benefit of being certified for Cisbio Bioassays HTRF® technology. ZERO BIAS - scores, article reviews, protocol conditions and moreThe NanoRacks Plate Reader-2 is a reconfigured SpectraMax M5e, one of Molecular Devices’ most reliable, durable, and feature-rich microplate readers, and has been configured to operate comfortably in the microgravity environment of the space station. 5, Z’ = 0.